HY01 Oil in water Laboratory
+
  • HY01 Oil in water Laboratory

HY01

The GNST-HY01 infrared spectrophotometer is used to determine the oil after the water sample is extracted with tetrachloroethylene under the condition of pH ≤ 2; the petroleum is determined after the extract is adsorbed with magnesium silicate to remove polar substances such as animal and plant oils. The content of oil and petroleum is calculated based on the correction coefficient by the absorbance A2930, A2960 and A3030 at the wave numbers of 2930cm-1 (stretching vibration of C-H bond in CH2 group), 2960cm-1 (stretching vibration of C-H bond in CH3 group) and 3030cm-1 (stretching vibration of C-H bond in aromatic ring); the content of vegetable oil is the difference between the content of oil and petroleum.

• The whole operation is odorless, friendly to operators and the environment, and pollution-free.

• Fast detection speed, short stabilization time, and it only takes 10 seconds to detect a sample.

• Low reagent usage: solves the problems of large amounts of extractants and samples, strong odor, and complex purification and cleaning.

• It can be used on-site and in the laboratory, and is in an aluminum alloy box that can be carried to the site for testing.

• Low detection limit and high accuracy.

Name

Parameters

Detection method

According to HJ637-2018 standard, "Infrared spectrophotometry"

Method detection limit

<0.04mg/L (sample volume 50mL, extract volume 10mL), <0.02mg/L (sample volume 500mL, extract volume 50mL), <0.002mg/L (sample volume 1000mL, extract volume 10mL)

Instrument detection limit

<0.10mg/L (3 times standard deviation of 11 times of tetrachloroethylene blank solution)

Accuracy

<±2% (20-100mg/L oil standard sample measurement 11 times)

Repeatability

RSD <0.2% (10-100mg/L oil standard sample measurement 11 times) RSD <0.6% (1-10mg/L oil standard sample measurement 11 times)

Linear correlation coefficient

No need to manually adjust the zero point, the software intelligently controls the adaptive automatic zeroing, no baseline drift

Oil measurement scanning speed

Full spectrum scan 10 seconds, three wave number scan 4 seconds

Operating system

2.0 version intelligent real-time operating system, 8-inch color touch screen voice prompt

Data storage

The instrument can store 262,000 records of data with spectrum, and there is no upper limit for data storage when connected to a computer

Using environment

Temperature range 5°℃ -45℃℃, humidity ≤90%

Power supply mode

Built-in 12V lithium battery, can be used for more than 24 hours after charging

Host size

Host size 37cm (length) x27cm (width) x 12cm (height)

Host weight

6.5kg

Keywords:

HY01 Oil in water Laboratory

HY01 Oil in water Laboratory
+
  • HY01 Oil in water Laboratory

HY01 Oil in water Laboratory

The GNST-HY01 infrared spectrophotometer is used to determine the oil after the water

Classification


Get A Quote

If you have any suggestions, please leave a message or send an email to us, and we will reply to you within 1 working day after receiving the message email.

Submit

Related Products

GNST-009S

009S can help you test residual chlorine, total residual chlorine, chlorine dioxide, and ozone. Using spectrophotometry. Convenient for you to take it out for testing at any time

100F

The 100F multi parameter controller is equipped with 12 interfaces, which can connect different types of sensors and convert data using the electrode method. It is suitable for sewage disposal、Steel metallurgy、Agricultural breeding、Paper printing、waterworks、University research、Pharmaceuticals、Rivers and lakes、petrochemical industry、Irrigation of farmland

GNST-608E

This is a powerful tap water monitoring instrument, paired with 5 to 10 sensors. Suitable for swimming pools, water plants, sewage treatment plants, rivers, lakes, and any place that requires real-time monitoring of water quality

GNST-800D

GNST-800D is a professional outdoor portable water quality detector with an integrated design.
< 1...456...21 >