GNST Series——800D
GNST-800D is a professional outdoor portable water quality detector with an integrated design. It can realize photometric detection, electrode detection and other functions. The built-in large-capacity lithium battery can realize the work without external power supply. The instrument adopts imported LED cold light source and optical structure, equipped with Genesite intelligent detection system, can perform data averaging calculation more than ten times per second, and imported ST32-bit ARM processor, which runs faster and more stable. Thus, the characteristics of intelligent, high performance, low noise and strong stability of water quality meter are realized by leaps and bounds. The instrument has built-in more than 800 water quality detection and emission standards for various industries, allowing you to quickly understand the emission limits of various pollutants in sewage.
Why do you need 800D?
Portable design, built-in large-capacity lithium battery, can be used for outdoor water sample determination.
Imported LED cold light source has an optical life of 200,000 hours, stable performance, and accurate test results.
Equipped with Genesite intelligent detection system, it can perform data averaging calculations more than a dozen times per second, and filter out interference with filtering algorithms to improve the accuracy of detection data.
Imported ST32-bit ARM processor, faster operation speed and stronger stability.
Internet of Things function, unlimited data storage Suijing cloud server.
It can support exporting detection data and updating programs through the built-in USB interface.
The instrument has built-in more than 800 water quality testing and emission standards for various industries, allowing you to quickly understand the emission limits of various pollutants in sewage.
The dilution system does not require manual calculations to meet the needs of users to detect sewage of different concentrations.
8-inch 2K ultra-clear color touch screen, clear image quality, sensitive response.
ABS material, high-strength, corrosion-resistant, high-temperature resistant shell.
Automatic printing of test results, batch testing, guided testing mode and other functions.
The guided operating system and flat UI design allow users to quickly complete pollutant testing for the first time.
800D can help you solve?
• The spectrophotometric detection project supports the determination of more than 40 water pollutants such as ammonia nitrogen, chromaticity, suspended solids, turbidity, heavy metals, etc.
• The electrode method detection project supports PH, turbidity, conductivity, dissolved oxygen, salinity, etc.
• High-precision digital sensor, with built-in temperature compensation function, improves the accuracy of detection data.
• Aviation connector, automatic identification of different digital sensors.
• The electrode method and spectrophotometry method are combined to basically cover all the needs of outdoor water quality detection, which is convenient and worry-free.
Product Parameters
|
Name |
Parameters |
Name |
Parameters |
|
Model |
GNST-800D Portable Water Quality Tester |
Test method |
Electrode method, spectrophotometry |
|
Resolution |
0.001 |
Ambient temperature |
5-40°C |
|
Storage data |
1 million |
Relative humidity |
<85%RH |
|
Power |
5W |
Power supply |
12v 3A |
|
Lithium battery |
4000mAH |
Dimensions |
390x290x150mm (length x width x height) |
|
Light source life |
200,000 hours |
Weight |
6.8kg |
Spectrophotometry test items
|
Items |
Range |
Detection method |
|
COD |
0-20000mg/L |
Potassium dichromate spectrophotometry |
|
Total phosphorus |
0-20mg/L |
Ammonium molybdate spectrophotometry |
|
Suspended solids |
0-400mg/L |
Direct colorimetry |
|
Color |
0-500° |
Platinum cobalt color system |
|
Copper |
0-100mg/L |
2,9-dimethyl-1,10-phenanthroline spectrophotometry |
|
Hexavalent chromium |
0-20mg/L |
Diphenylcarbazide spectrophotometry |
|
Iron |
0-100mg/L |
Phenanthroline spectrophotometry |
|
Manganese |
0.5-200mg/L |
Potassium periodate spectrophotometry |
|
Ferrous iron |
0-100mg/L |
Phenanthroline spectrophotometry |
|
Sulfate |
5-500mg/L |
Ammonium molybdate spectrophotometry |
|
Residual chlorine |
0-20mg/L |
N,N-diethyl-1,4-phenylenediamine spectrophotometry |
|
Cyanide |
0-10mg/L |
Volumetric and spectrophotometric methods |
|
Nitrate nitrogen |
0-100mg/L |
Chromotropic acid method |
|
Chloride |
0-100mg/L |
Mercury thiocyanate spectrophotometry |
|
Fluoride |
0-20mg/L |
Fluorine reagent spectrophotometry |
|
Permanganate index |
0.5-5mg/L |
Potassium permanganate oxidation spectrophotometry |
|
Ammonia nitrogen |
0-25mg/L |
Salicylic acid spectrophotometry |
|
Total hardness |
4-600mg/L |
EDTA titration method |
|
Total alkalinity |
4-2000mg/L |
Hydrochloric acid titration method |
|
Ozone |
0-20mg/L |
DPD spectrophotometry |
|
Silicon dioxide |
0-500mg/L |
Silica molybdenum yellow spectrophotometry |
|
Urea |
0-20mg/L |
Diacetyl monoxime spectrophotometry |
|
Volatile fatty acids |
0-5000mg/L |
Colorimetric method |
|
Ammonia nitrogen (seawater) |
0-5mg/L |
Sodium hypobromite oxidation method |
|
COD (high chlorine) |
200-1500mg/L |
Potassium dichromate spectrophotometry |
|
Ammonia nitrogen |
0-125mg/L |
Nessler's reagent method |
|
Total nitrogen |
0-100mg/L |
Alkaline potassium persulfate digestion photometry |
|
Turbidity |
0-500NTU |
Formazine spectrophotometry |
|
Nickel |
0-50mg/L |
Dimethylglyoxime spectrophotometry |
|
Total chromium |
0-20mg/L |
Diphenylcarbazide spectrophotometry |
|
Regulated |
0-20mg/L |
PAN spectrophotometry |
|
Nitrite nitrogen |
0-10mg/L |
Cadmium reagent spectrophotometry |
|
Total residual chlorine |
0-50mg/L |
Xylenol orange spectrophotometry |
|
Sulfide |
0-10mg/L |
Nitrite nitrogen |
|
Phosphate |
0-20mg/L |
N,N-diethyl-1,4-phenylenediamine spectrophotometry |
|
Volatile phenol |
0-10mg/L |
Methylene blue spectrophotometry |
|
Aniline |
0-20mg/L |
Ammonium molybdate spectrophotometry |
|
Anionic surfactant |
0-50mg/l |
4-aminoantipyrine spectrophotometry |
|
Aluminum |
0-50mg/L |
N-(1-naphthyl)ethylenediamine azo spectrophotometry |
|
Silver |
0-20mg/L |
Methylene blue spectrophotometry |
|
Formaldehyde |
0-5mg/L |
Chrome azuro S spectrophotometry |
|
Chlorine dioxide |
0-10mg/L |
3.5-Br2-PADAP spectrophotometry |
|
Cyanuric acid |
0-50mg/L |
Acetylacetone spectrophotometry |
|
Phenolphthalein alkalinity |
0-40mg/L |
DPD spectrophotometry |
|
Soft water hardness |
5-250mg/L |
Turbidimetry |
|
Cobalt |
4-2000mg/L |
Methyl red titration |
Electrode method detection items
|
Items |
Range |
Detection method |
|
PH |
0-14PH |
Glass electrode method |
|
Salinity |
0-3000PPM |
Electrode method |
|
Turbidity |
0-1000NTU |
90° scattered light method |
|
Dissolved oxygen |
0-20mg/L |
Fluorescent electrode method |
|
Conductivity |
0-5000uS/cm |
Electrode method |
|
COD |
0-370mg/L |
UV ultraviolet light method |
|
Ammonia nitrogen |
0-100mg/L |
Coated ion electrode method |
|
Suspended solids |
0-15000mg/L |
Infrared scattered light method |
|
Sludge concentration |
0.01-120000mg/L |
Infrared scattered light method |
|
Chlorophyll |
0-400μg/L or 0-100RFU |
Fluorescent electrode method |
|
Blue-green algae |
0-200000cells/mL |
Fluorescent electrode method |
|
TOC |
0-250mg/L |
UV ultraviolet light method |
|
TDS |
0-133000PPM |
Electrode method |
|
ORP |
-1500-1500mV |
Platinum electrode |
|
Oil in water |
0-50ppm or 0-0.4FLU |
Ultraviolet fluorescence method |
|
Residual chlorine |
0-20mg/L |
Constant voltage method |
|
Ozone |
0-20mg/L |
Constant voltage method |
|
Chlorine dioxide |
0-20mg/L |
Constant voltage method |
|
Color |
0-500 degrees |
Electrode method |
|
Nitrate |
0-14000ppm |
Electrode method |
|
Nitrates |
0-100mg/L |
Coated ion selection method |
|
Nitrite |
0-100mg/L |
Coated ion selection method |
|
Calcium ion |
0-100mg/L |
Coated ion selection method |
|
Potassium ion |
0-100mg/L |
Coated ion selection method |
|
Chloride ion |
0-100mg/L |
Coated ion selection method |
|
Fluoride ion |
0-100mg/L |
Coated ion selection method |
Keywords:
GNST-800D
GNST-800D
Contact Us
Classification
Related Products
Sludge Concentration Sensor&Controller