Online Ammonia Nitrogen Meter
Online Ammonia Nitrogen Meter
Online Ammonia Nitrogen Meter
+
  • Online Ammonia Nitrogen Meter
  • Online Ammonia Nitrogen Meter
  • Online Ammonia Nitrogen Meter

Specifications

Ammonia nitrogen sensor
Measuring range 0.1...18000ppm
Principle Ion-selective method
Temperature range 0-50℃
Pressure range 0...1bar
Process connection 3/4,M39*1.5,G1
Protection grade Ip68
Shell material PPS,ABS,PC,316L SS
Installation Immersion type/Flow through type
Cable length 5m (standard)
Interference Na +,K +
Controller
Measuring range 0-20000ppm
Display Back light, dot matrix LCD display
Resolution 0.01 (<1ppm); 0.1 (<10ppm); other 1ppm
Accuracy ±0.01ppm; ±0.1ppm; ±1ppm;
Repeatability ±1.0%FS
Ambient temperature 0~70℃
Relative humidity (65±20)%
Alarm output double relay
Digital output RS485
Power supply AC220V±10% or DC24V
Certification CE

 

Sensor installation

Sensor calibration

It is recommended that users be put into use after calibration.
It is recommended to use the two-point method for calibration, usually with 1.000ppm solution calibrate the zero point, then the slopeis determined with the solution of 10.000ppm.  The electrode should be calibrated in fresh solution. The standard solution can be set, and the second standard solution should be larger than the solution to be tested.Users are recommended to calibrate the sensor every 1 to 2 months.

Installation site

CE certification

Keywords:

Online Ammonia Nitrogen Meter

Related Downloads

Online Ammonia Nitrogen Meter
Online Ammonia Nitrogen Meter
Online Ammonia Nitrogen Meter
+
  • Online Ammonia Nitrogen Meter
  • Online Ammonia Nitrogen Meter
  • Online Ammonia Nitrogen Meter

Online Ammonia Nitrogen Meter

GENESITE Ammonia nitrogen Meter in the range of 0.1...18000ppm are measured and displayed using a controller with RS485 Modbus RTU protocol .Ammonia nitrogen sensor with ATC functions.

Applications

Metallurgy, electric power, pharmaceuticals, chemical industry, petroleum, water treatment, food industry, etc.

Get A Quote

If you have any suggestions, please leave a message or send an email to us, and we will reply to you within 1 working day after receiving the message email.

Submit

Related Products

GNST-900P

Automatic temperature compensation ensures accurate measurement across the entire range.

SJ-BOD-80S Bod only Laboratory

SJ-BOD-80S intelligent BOD meter is based on the national standard "HJ505-2009" 5-day biochemical

12HLX COD

The GNST-12HLX COD reflux digester uses a glass burr reflux tube instead of a spherical reflux tube

SJ16X Laboratory

The SJ-16X multifunctional rapid digestion instrument is an economical rapid digestion device
< 1234...43 >